Regarding the 15 Degree Calculation
Hello,
We kindly ask you to send us the 15 Degree (penalty) percentage rate you have decided on as management. The provision “Room temperatures in independent units heated by central systems shall be set to at least 15 °C.“ is found in the Heating Regulation. However, the regulation does not include a sanction calculation for the 15 Degree rule. In other words, there is no statement on how it should be calculated. (Regulation https://www.mevzuat.gov.tr/mevzuat?MevzuatNo=12084&MevzuatTur=7&MevzuatTertip=5 )
For this reason, in order to offer you this calculation, we at Apsiyon can apply the following calculation in the system based on the proposal prepared by the Chamber of Engineers.
| We are informing you of the Penalty Consumption Calculation with the formulas below. Total Consumption from the Boiler / Block Total Unit m2 = X X * Unit m2 = Y Y * Specified Penalty Percentage = Penalty Consumption | ||||||
For this calculation to be applied, it is enough for you, our managers, to tell us the percentage rate to be used as the basis for the calculation, according to the decision you have taken as management. In our attached sample calculation file, you can see how this rate takes effect and what it is based on.
The rate must be obtained from you. As we mentioned, since there is no legal requirement for how it should be done or for a specified calculation, we process it based on the decision taken by your Board of Management.
If it will not be applied, it is enough to reply by email saying "15 degrees will not be applied in our project". If there is no reply, the system will automatically be set up with 15 degrees not applied.
If 15 degrees will be applied, we kindly ask you to reply with one of the two options we describe below.
1- It is enough to set your own rate as management, fill in the sample text below, enter it in your Decision Book, and send us a photo or scanned copy of your Decision Book with stamp and signature.
………………….. Management,
In line with the provision stated in Paragraph 6 of Article 5, titled “Applications”, of the Regulation on the Sharing of Heating and Domestic Hot Water Expenses in Central Heating and Domestic Hot Water Systems, which reads “Room temperatures in independent units heated by central systems shall be set to at least 15 °C.”, it has been decided that room temperatures in the independent units in our site shall be set to at least 15 degrees, and that independent units that turn off the heating system shall be invoiced at a Fixed Rate of %................,
by unanimous vote.
(If you have set a different rate for each period, instead of a fixed rate you can also send the rates to be applied in each period separately, for example November 40%, December 45%, January 50%)
2- It is enough to fill in the sample text below with the rates we at Apsiyon obtained for you from the Chamber of Engineers, enter it in your Decision Book, and send us a photo or scanned copy of your Decision Book with stamp and signature.
………………….. Management,
In line with the provision stated in Paragraph 6 of Article 5, titled “Applications”, of the Regulation on the Sharing of Heating and Domestic Hot Water Expenses in Central Heating and Domestic Hot Water Systems, which reads “Room temperatures in independent units heated by central systems shall be set to at least 15 °C.”, it has been decided that room temperatures in the independent units in our site shall be set to at least 15 degrees, and that independent units that turn off the heating system shall be invoiced according to the distribution period rate recommended by the Chamber of Mechanical Engineers,
by unanimous vote.
(The Chamber of Engineers rates are attached to the email)
We look forward to your written replies with the decision to be processed at iot@apsiyon.com .
Best regards,